Premium Alternating Air Pressure Mattress
A pressure pad for a medical or standard bed at the top end of the price range. Ask the district nurse whether this level of system is needed.
An alternating pressure mattress uses a pump to inflate and deflate rows of air cells in turn, so the parts of the body touching the mattress keep changing. It is used for people who spend long periods in bed and are at risk of skin damage, and the type you need depends on that risk, which should be assessed by a nurse or occupational therapist.
The mattress or overlay is made of tubes or bubbles of air, connected to a quiet electric pump that hangs on the bed end. The pump fills alternate cells while others empty, then swaps them over in a regular cycle. This means no part of the body rests on the same point for too long. Most pumps have a comfort setting adjusted to the user’s weight, and an alarm if the power fails or the pressure drops.
| Type | Description | Typical Use |
|---|---|---|
| Bubble pad overlay | Thin pad of small air bubbles on top of the existing mattress | Lower-risk users at home |
| Cell overlay | Deeper tubes on top of the existing mattress | Moderate risk, with a firm base mattress |
| Replacement mattress system | Full-depth air mattress replacing the normal one | Higher risk, usually supplied after assessment |
| Hybrid mattress | Foam base with air cells on top | Users who need a stable edge for getting in and out |
Higher-risk users are normally given a full replacement system through their community nursing team. The cheaper overlays sold online are mostly bubble or cell pads, which are designed for lower levels of risk.
Pressure ulcers, also called bed sores or pressure sores, develop when skin and the tissue beneath stay under pressure for too long. A mattress is only one part of looking after the skin. Regular changes of position, good nutrition and hydration, keeping skin clean and dry and checking it daily all matter. If you notice red, purple or darkened patches that do not fade, or any broken skin, contact the GP or district nurse promptly. The NHS pressure ulcers page explains the signs and who is most at risk.
Check the pump is running and the cells are inflating every day. Feel under the user’s hips with a flat hand to check they are not bottoming out on the base mattress.
Overlays are made to fit a standard single bed in most cases, with a few made for larger or profiling beds. Measure the base mattress before buying and check the overlay will not overhang the edges. Each system lists a user weight range for the pump settings, so choose one that covers the person comfortably. On a profiling bed, make sure the hoses and power cable have enough slack to move when the bed raises or tilts, and that the overlay does not slide down when the head end is raised.
Wipe the overlay with a mild detergent solution and dry it well, following the maker’s instructions; harsh chemicals can damage the cells. Use a breathable waterproof sheet if there is a risk of spills or incontinence, but avoid plastic sheets that trap heat and moisture. Check the cells regularly for holes or splits, and the hose connectors for cracks. A slowly deflating cell usually means a puncture or a loose connection.
Most modern pumps are quiet, but some people notice a gentle hum or the feeling of movement at first. Overlays raise the height of the bed, so check bed rails still reach high enough. The mattress surface can feel less stable for getting in and out, which matters for people who sit on the edge of the bed to stand. Keep the pump away from pets, and never use pins or sharp objects near the cells.
Yes, if you are assessed as at risk: the community nursing team or the hospital usually provides one, often on discharge. Ask the GP or district nurse for an assessment rather than buying straight away, especially if the person already has any skin damage. Buying privately can make sense for low-risk users or for a spare overlay.
People who sit for long periods also need a suitable cushion, because sitting puts high pressure on a small area. Our alternating pressure cushion guide and the guide to wheelchair cushions for pressure care cover seating.
The overlays and pumps below were in stock when we checked each listing. Ask a nurse or occupational therapist which level of support is right before buying.
It depends on the system. Follow the maker’s settings and the advice of the nurse who assessed the user.
Check the instructions. Most overlays work best on a firm base mattress.
The cells slowly deflate. Many pumps sound an alarm, and some have a transport valve that holds air for a while.
For lower-risk users it may be. Higher-risk users need a system chosen after a professional assessment.
A pressure pad for a medical or standard bed at the top end of the price range. Ask the district nurse whether this level of system is needed.
Topper with a pump marketed as whisper quiet, which matters in a shared bedroom.
Pad and electric pump at a modest price. A common choice as an overlay on an existing mattress, and easy to lift off for washing the bed linen.
A full replacement system that combines low air loss with alternating pressure. Much dearer, and usually only for higher risk.
A thicker air topper, about 13 cm deep, made for use at home. It sits on top of the existing mattress, so the bed stays the same height.
Air pad with micro vents designed to keep air moving under the skin, which can help with heat and sweating in bed.
Cell mattress with its own compressor, sold for anti-decubitus care. Check the length and width against your bed before ordering.
Air mattress with a digital compressor display, so settings are easy to read.
Topper for home or hospital beds aimed at people who spend long periods in bed.
End flaps tuck under the mattress to stop the pad shifting.